Reference Guide
Event ID — 2441
Description The PCIe solid state device identified in the message has turned off because the critical temperature threshold of
the device was exceeded.
Severity Error
Cause and Action Cause: None
Action: Contact your service provider.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
904
Event ID — 2442
Description The reliability of the PCIe solid state device identified in the message degraded. Data loss is possible.
Severity Error
Cause and Action Cause: None
Action: Back up the data on the device, and contact your service provider for further instructions.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
904
Event ID — 2443
Description
The volatile memory backup device on the PCIe solid state device identified in the message is no longer functional.
Data loss is possible.
Severity Error
Cause and Action Cause: None
Action: Back up the data on the device, and contact your service provider for further instructions.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
904
Event ID — 2444
Description
The Patrol Read operation was manually stopped before completion.
Severity Informational
Cause and Action Cause: User Triggered Task
Action: If desired, restart the Patrol Read operation at a later time.
Storage Management Message Reference 159