Reference Guide
Event ID — 2401
Description Configuration command could not be committed to disk. Configuration has to be re applied.
Severity Failure / Error
Cause and Action Cause: The virtual disk configuration command did not succeed.
Action: Check for the recent configuration that has not taken effect. Re-apply the configuration.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
754
Event ID — 2402
Description Changing the Physical Disk Power status from 1% to 2% failed.
Severity Failure / Error
Cause and Action Cause: When changing the Physical Disk Power status fails.
Action: Replace the physical disk.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
904
Event ID — 2403
Description
Virtual Disk is available.
Severity OK / Normal / Informational
Cause and Action Cause: The operating system detects the newly created virtual disk.
Action: None.
NOTE: This alert also appears when a CacheCade is created but is not available for the operating
system (as it is a CacheCade and not a Virtual Disk).
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1201
Event ID — 2404
Description
Virtual Disk is not available.
Severity OK / Normal / Informational
Cause and Action Cause: The operating system does not detect the newly created virtual disk.
Storage Management Message Reference 151