Reference Guide
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1051
Event ID — 2354
Description Enclosure firmware download in progress.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is provided for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
851
Event ID — 2355
Description
Enclosure firmware download failed.
Severity Warning / Non-critical
Cause and Action Cause: The system was unable to download firmware to the enclosure. The controller may have lost
communication with the enclosure. There may have been problems with the data transfer or the download media
may be corrupt.
Action: Attempt to download the enclosure firmware again. If problems continue, verify that the controller can
communicate with the enclosure. Make sure that the enclosure is powered on. Check the cables. See the Cables
Attached Correctly section for more information on checking the cables. Verify the health of the enclosure and its
components. To verify the health of the enclosure, select the enclosure object in the tree view. The Health subtab
displays a red X or yellow exclamation point for enclosure components that are failed or degraded.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2090
SNMP Trap
Numbers
853
Event ID — 2356
Description
SAS SMP Communications error %1.
Severity Critical / Failure / Error
Cause and Action Cause: The text for this alert is generated by the firmware and can vary depending on the situation. The
reference to SMP in this text refers to SAS Management Protocol.
Action: There may be a SAS topology error. See the hardware documentation for information on correct SAS
topology configurations. There may be problems with the cables such as a loose connection or an invalid cabling
configuration. See the Cables Attached Correctly section for more information on checking the cables. See the
hardware documentation for information on correct cabling configurations. Verify that the firmware is a supported
version.
138 Storage Management Message Reference