Reference Guide

Event ID — 2337
Description The controller is unable to recover cached data from the battery backup unit (BBU).
Severity Critical / Failure / Error
Cause and Action Cause: The controller was unable to recover data from the cache. This may occur when the system is without
power for an extended period when the battery is discharged.
Action: Check if the battery is charged and in good health. When the battery charge is unacceptably low, it
cannot maintain cached data. Check if the battery has reached its recharge limit. The battery may need to be
recharged or replaced.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2101
SNMP Trap
Numbers
1154
Event ID — 2338
Description The controller has recovered cached data from the BBU.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1151
Event ID — 2339
Description
The factory default settings have been restored.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
751
Event ID — 2340
Description
The BGI completed with uncorrectable errors.
Severity Critical / Failure / Error
Cause and Action Cause: The BGI task encountered errors that cannot be corrected. The virtual disk contains physical disks that
have unusable disk space or disk errors that cannot be corrected.
Storage Management Message Reference 133