Reference Guide

Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
751
Event ID — 2327
Description The NVRAM has corrupted data. The controller is reinitializing the NVRAM.
Severity Warning / Non-critical
Cause and Action Cause: The nonvolatile random access memory (NVRAM) is corrupt. This may occur after a power surge, a
battery failure, or for other reasons. The controller is reinitializing the NVRAM. The controller properties reset to
the default settings after the reinitialization is complete.
NOTE: The controller is taking the required corrective action. If this alert is generated often (such
as during each reboot), replace the controller.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2266
Local Response Agent (LRA) Number: 2060
SNMP Trap
Numbers
753
Event ID — 2328
Description
The NVRAM has corrupt data.
Severity Warning / Non-critical
Cause and Action Cause: The NVRAM has corrupt data. The controller is unable to correct the situation.
Action: Replace the controller.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 20601
SNMP Trap
Numbers
753
Event ID — 2329
Description
SAS port report: %1
Severity Warning / Non-critical
Cause and Action Cause: The text for this alert is generated by the controller and can vary depending on the situation. The %1
indicates a substitution variable. The text for this substitution variable is generated by the controller and is
displayed with the alert in the alert log. This text can vary depending on the situation.
Action: Run the PHY integrity test diagnostic. Make sure the cables are attached securely. If the problem
persists, replace the cable with a valid cable according to SAS specifications. If the problem still persists, you may
need to replace some devices such as the controller or EMM. See the hardware documentation for more
information.