Reference Guide
Event ID — 2323
Description The power supply is switched on.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Status: Alert 2323 is a clear alert for alerts 2313 and 2322.
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1001
Event ID — 2324
Description The AC power supply cable has been removed.
Severity Critical / Failure / Error
Cause and Action Cause: The power cable may be pulled out or removed. The power cable may also have overheated and become
warped and nonfunctional.
Action: Replace the power cable.
Related Alert
Information
Clear Alert Number: 2325
Related Alert Number: None
Local Response Agent (LRA) Number: 2091
SNMP Trap
Numbers
1004
Event ID — 2325
Description
The power supply cable has been inserted.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Status: Alert 2325 is a clear alert for alerts 2324 and 2312.
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1001
Event ID — 2326
Description
A foreign configuration has been detected.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes. The controller has physical disks that were moved from another
controller. These physical disks contain virtual disks that were created on the other controller. See the Import
Foreign Configuration and Clear Foreign Configuration section in the Server Administrator Storage Management
User’s Guide for more information.
Storage Management Message Reference 129