Reference Guide
Local Response Agent (LRA) Number: 2060
SNMP Trap
Numbers
753
Event Id — 2320
Description Single-bit ECC error. The DIMM is critically degraded.
Severity Critical / Failure / Error
Cause and Action Cause: The DIMM is malfunctioning. Data loss or data corruption may be imminent.
Action: Replace the DIMM immediately to avoid data loss or data corruption. The DIMM is a part of the controller
battery pack. See your hardware documentation for information on replacing the DIMM or contact technical
support.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2321
Local Response Agent (LRA) Number: 2061
SNMP Trap
Numbers
754
Event ID — 2321
Description
Single-bit ECC error. The DIMM is critically nonfunctional. There is no further reporting.
Severity Critical / Failure / Error
Cause and Action Cause: The DIMM is malfunctioning. Data loss or data corruption is imminent. No further alerts are generated.
Action: Replace the DIMM immediately. The DIMM is a part of the controller battery pack. See your hardware
documentation for information on replacing the DIMM.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2061
SNMP Trap
Numbers
754
Event ID — 2322
Description
The DC power supply is switched off.
Severity Informational
Cause and Action Cause: The power supply unit is switched off. Either a user switched off the power supply unit or it is defective.
Action: Check if the power switch is turned off. If it is turned off, turn it on. If the problem persists, check if the
power cord is attached and functional. If the problem is still not corrected or if the power switch is already turned
on, replace the power supply unit.
Related Alert
Information
Clear Alert Number: 2323
Related Alert Number: None
Local Response Agent (LRA) Number: 2091
SNMP Trap
Numbers
1001
128 Storage Management Message Reference