Reference Guide
Cause and Action Cause: The %1 indicates a substitution variable. The text for this substitution variable is generated by the utility
that ran the diagnostics and is displayed with the alert in the alert log. This text can vary depending on the
situation. This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
751
Event ID — 2316
Description Diagnostic message %1
Severity Critical / Failure / Error
Cause and Action Cause: A diagnostics test failed. The %1 indicates a substitution variable. The text for this substitution variable is
generated by the utility that ran the diagnostics and is displayed with the alert in the alert log. This text can vary
depending on the situation.
Action: See the documentation for the utility that ran the diagnostics for more information
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2061
SNMP Trap
Numbers
754
Event ID — 2318
Description
Problems with the battery or the battery charger have been detected. The battery health is poor.
Severity Warning / Non-critical
Cause and Action Cause: The battery or the battery charger is not functioning properly.
Action: Replace the battery pack.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2188
Local Response Agent (LRA) Number: 2100
SNMP Trap
Numbers
1153
Event ID — 2319
Description
Single-bit ECC error. The DIMM is degrading.
Severity Warning / Non-critical
Cause and Action Cause: The DIMM is beginning to malfunction.
Action: Replace the DIMM to avoid data loss or data corruption. The DIMM is a part of the controller battery
pack. See your hardware documentation for information on replacing the DIMM or contact technical support.
Related Alert
Information
Clear Alert Number: 753
Related Alert Number: 2320
Storage Management Message Reference 127