Reference Guide

Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
751
Event ID — 2305
Description The physical disk is too small to be used for a rebuild.
Severity Warning / Non-critical
Cause and Action Cause: The physical disk is too small to rebuild the data.
Action: Remove the physical disk and insert a new physical disk that is the same size or larger than the disk that
is being rebuilt. The new physical disk must also use the same technology (for example, SAS or SATA) as the disk
being rebuilt. If the rebuild does not start automatically after you have inserted a suitable physical disk, then run
the Rebuild task. See the
Server Administrator Storage Management User’s Guide for more information.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2326
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
Event ID — 2306
Description
Bad block table is 80% full.
Severity Warning / Non-critical
Cause and Action Cause: The bad block table is used for remapping bad disk blocks. This table fills, as bad disk blocks are remapped.
When the table is full, bad disk blocks can no longer be remapped, and disk errors can no longer be corrected. At
this point, data loss can occur. The bad block table is now 80% full.
Action: Back up your data. Replace the disk generating this alert and restore from back up.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2307
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
Event ID — 2307
Description
Bad block table is full. Unable to log block %1.
Severity Critical / Failure / Error
Cause and Action Cause: The bad block table is used for remapping bad disk blocks. This table fills, as bad disk blocks are remapped.
When the table is full, bad disk blocks can no longer be remapped and disk errors can no longer be corrected. At
this point, data loss can occur. The %1 indicates a substitution variable. The text for this substitution variable is
displayed with the alert in the alert log and can vary depending on the situation.
Action: Replace the disk generating this alert. If necessary, restore your data from backup.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2048
Local Response Agent (LRA) Number: 2071
124 Storage Management Message Reference