Reference Guide

Event ID — 2298
Description The enclosure has a bad sensor %1.
Severity Warning / Non-critical
Cause and Action Cause: The enclosure has a bad sensor. The enclosure sensors monitor the fan speeds, temperature probes, and
so on. The % indicates a substitution variable. The text for this substitution variable is displayed with the alerts in
the alert log and can vary depending on the situation.
Action: See the hardware documentation for more information.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2090
SNMP Trap
Numbers
853
Event ID — 2299
Description Bad PHY %1
Severity Critical / Failure / Error
Cause and Action Cause: There is a problem with a physical connection or PHY. The %1 indicates a substitution variable. The text
for this substitution variable is displayed with the alert in the alert log and can vary depending on the situation.
Action: Contact your technical support.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2091
SNMP Trap
Numbers
854
Event ID — 2300
Description
The enclosure is unstable.
Severity Critical / Failure / Error
Cause and Action Cause: The controller is not receiving a consistent response from the enclosure. There could be a firmware
problem or an invalid cabling configuration. If the cables are too long, they degrade the signal.
Action: Power down all enclosures attached to the system and reboot the system. If the problem persists,
upgrade the firmware to the latest supported version. You can download the most current version of the driver
and firmware from the support site. Make sure the cable configuration is valid. See the hardware documentation
for valid cabling configurations.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2091
SNMP Trap
Numbers
854
Event ID — 2301
Description
The enclosure has a hardware error.
122 Storage Management Message Reference