Action: Assign a larger disk as the global hot spare.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
Event ID — 2278
Description The controller battery charge level is below a normal threshold.
Severity Warning
Cause and Action Cause: The battery is discharging. A battery discharge is a normal activity during the battery Learn cycle. The
battery Learn cycle recharges the battery. You should receive alert 2179 when the recharge occurs.
Action 1: Check if the battery Learn cycle is in progress. The battery also displays the Learn state while the Learn
cycle is in progress.
Action 2: If a Learn cycle is not in progress, replace the battery pack.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2199
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1153
Event ID — 2279
Description
The controller battery charge level is operating within normal limits.
Severity OK / Normal / Informational
Cause and Action Cause: This alert indicates that the battery is recharging during the battery Learn cycle. This alert is provided for
informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1151
Event ID — 2280
Description
A disk media error has been corrected.
Severity OK / Normal / Informational
Cause and Action Cause: A disk media error was detected while the controller was completing a background task. A bad disk block
was identified. The disk block has been remapped.
Action: Consider replacing the disk. If you receive this alert frequently, be sure to replace the disk. You should also
routinely back up your data.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None