Release Notes
interactive applications properly for an Alert Action. Also, make sure the Interactive Services Detection service is running, to see the
interface or prompt displayed by the interactive application. Once these changes are made, the operating system displays the
Interactive services dialog detection dialog box to provide access to the interactive application interface or prompt. After upgrading
Windows Server 2003 x64 to Windows Server 2008 x64 with Server Administrator installed, the application UI does not display all the
expected instrumentation pages. The Server Administrator installation must be repaired. Go to Start > Settings > Control panel > Add
Remove Programs > Select Change on the Server Administrator installation and select the Repair option to correct the issue.
• DF330800: Server Administrator Web server local user login fails on the Windows 2008 R2 Managed Node. When a Windows 2008 R2
Managed Node is added to a domain, logging in from any Server Administrator Web Server to that Windows 2008 R2 Managed Node
will fail with local user or local power-user credentials. Only the credentials of a local Administrator or Domain user will work, with a
prerequisite that all required winrm congurations have been applied.
Issues of Server Administrator on Microsoft Windows 2012
Operating Systems
• BITS068231: On Windows Server 2012 with Server Administrator (32-bit), Base Memory Address and IRQ values are not available for
any Network Interface Cards.
Issues of Server Administrator on All Supported Operating
Systems
• BITS107804: On PowerEdge R210 II and T110 II servers, clearing the Shutdown OS First check box and performing a reboot using the
‘Reboot’ option does not reboot the servers. After performing these steps if you refresh the Page, the options on the Remote
Shutdown page are not displayed.
• On Dell PowerEdge T110 II systems, the following Server Administrator BIOS settings are not consistent with the F2 BIOS setup
settings:
– Watchdog timer: Server Administrator displays the option as disabled, but F2 BIOS allows to change the setting.
– Embedded Video Controller: Server Administrator provides options to enable or disable, but in F2 BIOS the option is grayed out.
– TPM Security: Server Administrator does not allow to change the settings, but F2 BIOS allows to change the settings.
– System Prole State: Server Administrator does not allow to make changes, but F2 BIOS allows to make the changes.
– Memory Testing: Server Administrator does not support this feature, but F2 BIOS supports this feature.
– SRIOV option: Server Administrator does not display this information, but F2 BIOS displays this feature.
• Due to non-availability of resources, inventory collector may terminate unexpectedly and restart. If this occurs, the folder C:\Temp
\invcol may be left as an artifact. The presence of this folder does not aect the functionality of the inventory collection. The folder
can be deleted if required.
• After installing Server Administrator from the command prompt, typing an omreport or mcong command from the same prompt can
cause an error. Open a new command prompt window and type commands.
• If the command log page in the Server Administrator GUI displays an error message indicating that the XML is malformed, you must
clear the command log from the CLI using the omcong system cmdlog action=clear command
• After a Reset to Defaults operation of the Integrated Remote Access Controller, the rst user conguration, operation fails if it is a
single-user conguration item (such as enabling or disabling a user or changing user name). Always change a combination of two-user
conguration items (such as enabling or disabling a user and changing user name) concurrently during your rst conguration operation.
• While typing the command omreport system version -outc <lename>, ensure that you specify an absolute path name for the output
le; else, the output le is empty. For example, c:\out.txt.
• Typing omreport system esmlog/alertlog/cmdlog -fmt tbl command on the CLI can result in XML parsing errors if the size of the log
is large. Use the GUI or the omreport system esmlog/alertlog/cmdlog CLI command to view the contents of the log.
• For complex omcong CLI commands that contain multiple set commands in one command line, the CLI may report a success status
for the command even if a part of the command failed. To avoid this issue, run only one command per command line. The current
settings can be conrmed by performing the corresponding omreport command.
• Some complex omcong CLI commands that contain multiple set operations have been modied to avoid the above problem. While
running a CLI command if the message, Error! Illegal combination of parameters is displayed, modify your command into several
simpler commands. Each command should change only one setting.