Reference Guide
Fatal Error Code Description Cause
C4 Incorrect memory conīguration. Memory population order not correct.
FE General failure after video. Check screen for the actual error message.
Operating System Generated System Events
Table 18. Operating System Generated System Events
Description Severity Cause
System Event: OS stop event OS
graceful shutdown detected
Information The operating system was shutdown/
restarted normally.
OEM Event data record (after
OS graceful shutdown/restart
event)
Information Comment string accompanying an operating
system shutdown/ restart.
System Event: OS stop event
runtime critical stop
Critical The operating system encountered a critical
error and was stopped abnormally.
OEM Event data record (after
OS bugcheck event)
Information Operating system bugcheck code and
parameters.
A critical stop occurred
during OS load.
Critical The operating system encountered a critical
error and was stopped abnormally while
loading.
A runtime critical stop
occurred.
Critical The operating system encountered a critical
error and was stopped abnormally.
An OS graceful stop occurred.
Information The operating system was stopped.
An OS graceful shut-down
occurred.
Information The operating system was shut down
normally.
Cable Interconnect Events
The cable interconnect messages in the table are used for detecting errors in the hardware cabling.
Table 19. Cable Interconnect Events
Description Severity Cause
Cable sensor <Name/
Location>Configuration error
was asserted.
Critical This event is generated when the cable is
not connected or is incorrectly connected.
Cable sensor <Name/
Location>Connection was
asserted.
Information This event is generated when the earlier
cable connection error was corrected.
The <name> cable or
interconnect is not connected
or is improperly connected.
Critical This event is generated when the named
cable or interconnect is not connected or is
incorrectly connected.
234 System Event Log Messages for IPMI Systems