Reference Guide

Severity Warning / Non-critical
Cause and Action Cause: A disk is degraded and has received a SMART alert (predictive failure). The disk is likely to fail in the near
future.
Action: Replace the disk that has received the SMART alert. If the physical disk is a member of a nonredundant
virtual disk, then back up the data before replacing the disk.
CAUTION: Removing a physical disk that is included in a non-redundant virtual disk causes the virtual
disk to fail and may cause data loss.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
Event ID — 2111
Description Failure prediction threshold exceeded due to test.
Severity Warning / Non-critical
Cause and Action Cause: A disk has received a SMART alert (predictive failure) due to test conditions.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
Event ID — 2112
Description
Enclosure was shut down.
Severity Critical / Failure / Error
Cause and Action Cause: The physical disk enclosure is either hotter or cooler than the maximum or minimum allowable temperature
range.
Action: Check for factors that may cause overheating or excessive cooling. For example, verify that the enclosure
fan is working. You should also check the thermostat settings and examine whether the enclosure is located near a
heat source. Make sure the enclosure has enough ventilation and that the room temperature is not too hot or too
cold. See the enclosure documentation for more diagnostic information.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Storage Management Message Reference 81