Reference Guide

SNMP Trap
Numbers
1151
Event ID — 2106
Description SMART FPT exceeded.
Severity Warning / Non-critical
Cause and Action Cause: A disk on the specied controller has received a SMART alert (predictive failure) indicating that the disk is
likely to fail in the near future.
Action: Replace the disk that has received the SMART alert. If the physical disk is a member of a non-redundant
virtual disk, then back up the data before replacing the disk.
CAUTION: Removing a physical disk that is included in a non-redundant virtual disk causes the virtual
disk to fail and may cause data loss.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
Event ID — 2107
Description
SMART conguration change.
Severity Critical / Failure / Error
Cause and Action Cause: A disk has received a SMART alert (predictive failure) after a conguration change. The disk is likely to fail
in the near future.
Action: Replace the disk that has received the SMART alert. If the physical disk is a member of a non-redundant
virtual disk, then back up the data before replacing the disk.
CAUTION: Removing a physical disk that is included in a non-redundant virtual disk causes the virtual
disk to fail and may cause data loss.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2071
SNMP Trap
Numbers
904
Event ID — 2108
Description
SMART warning.
Storage Management Message Reference 79