SNMP Trap
Numbers
901
Event ID — 2094
Description Predictive Failure reported.
Severity Warning / Non-critical
Cause and Action Cause: The physical disk is predicted to fail. Many physical disks contain Self Monitoring Analysis and Reporting
Technology (SMART). When enabled, SMART monitors the health of the disk based on indications such as the
number of write operations that have been performed on the disk.
Action: Replace the physical disk. Even though the disk may not have failed yet, it is strongly recommended that
you replace the disk.
If this disk is part of a redundant virtual disk, perform the Oine task on the disk; replace the disk; the rebuild
starts automatically.
NOTE: If you put the drive in a dierent slot, you need to assign it as a hot spare for the rebuild to start
automatically.
If this disk is a hot spare, then unassign the hot spare; perform the Prepare to Remove task on the disk; replace
the disk; and assign the new disk as a hot spare.
CAUTION: If this disk is part of a non-redundant disk, back up your data immediately. If the disk fails, you
cannot recover the data.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
Event ID — 2095
Description
SCSI sense data %1.
Severity OK / Normal / Informational
Cause and Action Cause: A SCSI device experienced an error, but may have recovered.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2273
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
751, 851, 901
Storage Management Message Reference 75