Reference Guide
Event ID — 2048
Description Device failed.
Severity Critical / Failure / Error
Cause and Action Cause: A storage component such as a physical disk or an enclosure has failed. The failed component may have
been identied by the controller while performing a task such as a rescan or a check consistency.
Action: Replace the failed component. You can identify which disk has failed by locating the disk that has a red “X”
for its status. Perform a rescan after replacing the failed component.
Related Alert
Information
Clear Alert Number: 2121
Related Alert Number: 2095, 2201, 2203
Local Response Agent (LRA) Number: 2051, 2061, 2071, 2081, 2091, 2101
SNMP Trap
Numbers
754, 804, 854, 904, 954, 1004, 1054, 1104, 1154, 1204
Event ID — 2049
Description
Physical disk removed.
Severity Warning / Non-critical
Cause and Action Cause: A physical disk has been removed from the disk group. This alert can also be caused by loose or defective
cables or by problems with the enclosure.
Action: If a physical disk was removed from the disk group, either replace the disk or restore the original disk. On
some controllers, a removed disk has a red X for its status. On other controllers, a removed disk may have an
Offline status or is not displayed on the user interface. Perform a rescan after replacing or restoring the disk. If
a disk has not been removed from the disk group, then check for problems with the cables. See the online help for
more information on checking the cables. Ensure that the enclosure is powered on. If the problem persists, check
the enclosure documentation for further diagnostic information.
Related Alert
Information
Clear Alert Number: 2052
Related Alert Number: 2054, 2057, 2056, 2076, 2079, 2081, 2083, 2129, 2202, 2204, 2270, 2292, 2299, 2369
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
Event ID — 2050
Description
Physical disk oine.
Severity Warning / Non-critical
Cause and Action Cause: A physical disk in the disk group is oine. The user may have manually put the physical disk oine.
Storage Management Message Reference 61