Reference Guide

Chassis Location: <Name of chassis>
Previous state was: <State>
Battery sensor status: <status>
Severity Error
Cause A battery sensor in the specied system could not retrieve a value. The sensor location, chassis location, previous
state, and battery sensor status information is provided.
Event ID — 1706
Description
Battery sensor detected absence value Sensor location: <Location in chassis>
Chassis Location: <Name of chassis>
Previous state was: <State>
Battery sensor status: <status>
Severity Critical
Cause and Action Cause: A battery sensor in the specied system detected that a battery is absent. The sensor location, chassis
location, previous state, and battery sensor status information is provided.
Action: Check the battery to conrm the presence
Secure Digital SD Card Device Messages
The SD card device sensors monitor instrumented SD card devices in the system. The messages provide the status and error information
for SD card devices present in a chassis.
Event ID — 1750
Description
SD card device sensor has failed Sensor location: <Location in chassis>
Chassis Location: <Name of chassis>
Previous state was: <State>
SD card device type: <Type of SD card device>
SD card state: <State of SD card>
Severity Error
Cause An SD card device sensor in the specied system failed. The sensor location, chassis location, previous state, and
SD card device type information is provided. The SD card state is provided if an SD card is present in the SD card
device.
Server Management Messages 55