Reference Guide
Event ID — 1435
Description
The Non-Volatile Dual In-line Memory Module (NVDIMM) device in the slot mentioned in log, has lost persistency
and is placed in write-protect mode.
Severity Critical
Cause
Remove and reinstallthe Non-Volatile Dual In-line Memory Module (NVDIMM) device. If the issue persists, contact
the service provider. For information about removing and reinstalling the NVDIMM, see the system Owner's
Manual on the support site.
Hardware Log Sensor Messages
The hardware logs provide hardware status messages to systems management software. On certain systems, the hardware log is
implemented as a circular queue. When the log becomes full, the oldest status messages are overwritten when new status messages are
logged. On some systems, the log is not circular. On these systems, when the log becomes full, subsequent hardware status messages are
lost. Hardware log sensor messages listed provides status and warning information about the noncircular logs that may ll up, resulting in
lost status messages.
Event ID — 1550
Description
Log monitoring has been disabled
Log type: <Log type>
Severity Warning
Cause A hardware log sensor in the specied system is disabled. The log type information is provided.
Event ID — 1551
Description
Log status is unknown
Log type: <Log type>
Severity Information
Cause A hardware log sensor in the specied system could not obtain a reading. The log type information is provided.
Event ID — 1552
Description
Log size is no longer near or at capacity
Log type: <Log type>
Server Management Messages 49