Reference Guide

Event ID — 1427
Description
The Non-Volatile Dual In-line Memory Module (NVDIMM) device in the slot mentioned in log, is not responding and
is disabled.
Severity Critical
Cause Remove and reinstall the Non-Volatile Dual In-line Memory Module (NVDIMM) device. If the issue persists, contact
your service provider. For information about removing and reinstalling the NVDIMM, see the system Owner's
Manual on the support site.
Event ID — 1428
Description
The Non-Volatile Dual In-line Memory Module (NVDIMM) device in the slot mentioned in log, is unable to save the
data during the previous system shutdown operation or power loss.
Severity Critical
Cause Remove and reinstall the Non-Volatile Dual In-line Memory Module (NVDIMM) device. If the issue persists, contact
your service provider. For information about removing and reinstalling the NVDIMM, see the system Owner's
Manual on the support site.
Event ID — 1429
Description
The Non-Volatile Dual In-line Memory Module (NVDIMM) device in the slot mentioned in log, is unable to restore
the data that was saved in the previous 'save' operation.
Severity Critical
Cause Remove and reinstall the Non-Volatile Dual In-line Memory Module (NVDIMM) device. If the issue persists, contact
your service provider. For information about removing and reinstalling the NVDIMM, see the system Owner's
Manual on the support site.
Event ID — 1430
Description
An unsupported Non-Volatile Dual In-line Memory Module (NVDIMM) device is of unsupported conguration and
unable to operate as currently congured.
Severity Critical
Cause
Review the memory conguration and make sure the conguration is as per memory rules dened in the system
Owner's Manual on the support site.
Server Management Messages 47