Reference Guide
Cause The log was full, copied to backup, and cleared.
Event ID — 1000
Description
Server Administrator starting
Severity Information
Cause Server Administrator is beginning to initialize.
Event ID — 1001
Description
Server Administrator startup complete
Severity Information
Cause Server Administrator completed initialization.
Event ID — 1002
Description
A system BIOS update has been scheduled for the next reboot
Severity Information
Cause The user has chosen to update the ash basic input/output system (BIOS).
Event ID – 1003
Description
A previously scheduled system BIOS update has been canceled
Severity Information
Cause The user decides to cancel the ash BIOS update, or an error occurs during the ash.
Event ID — 1004
Description
Thermal shutdown protection has been initiated
Severity Error
Cause This message is generated when a system is congured for thermal shutdown due to an error event. If a
temperature sensor reading exceeds the error threshold for which the system is congured, the operating system
shuts down and the system powers o. This event may also be initiated on certain systems when a fan enclosure is
removed from the system for an extended period of time.
26 Server Management Messages