Reference Guide

Fatal Error Code Description Cause
8C SMI initialization failure. This error code indicates SMI initialization
failure.
C0 Shutdown test failure. This error code indicates a shutdown test
failure.
C1 POST Memory test failure. This error code indicates bad memory
detection.
C2 RAC conguration failure. Check screen for the actual error message.
C3 CPU conguration failure. Check screen for the actual error message.
C4 Incorrect memory conguration. Memory population order not correct.
FE General failure after video. Check screen for the actual error message.
Operating System Generated System Events
Table 18. Operating System Generated System Events
Description Severity Cause
System Event: OS stop event OS
graceful shutdown detected
Information The operating system was shutdown/
restarted normally.
OEM Event data record (after
OS graceful shutdown/restart
event)
Information Comment string accompanying an operating
system shutdown/ restart.
System Event: OS stop event
runtime critical stop
Critical The operating system encountered a critical
error and was stopped abnormally.
OEM Event data record (after
OS bugcheck event)
Information Operating system bugcheck code and
parameters.
A critical stop occurred
during OS load.
Critical The operating system encountered a critical
error and was stopped abnormally while
loading.
A runtime critical stop
occurred.
Critical The operating system encountered a critical
error and was stopped abnormally.
An OS graceful stop occurred.
Information The operating system was stopped.
An OS graceful shut-down
occurred.
Information The operating system was shut down
normally.
234 System Event Log Messages for IPMI Systems