Reference Guide

Event Message Severity Cause
Memory Mirrored redundancy
regained.
Information This event is generated when the
redundancy lost or degraded earlier is
regained in a mirrored memory
conguration.
Memory Spared redundancy
degraded.
Warning This event is generated when there is a
memory failure in a spared memory
conguration.
Memory Spared redundancy lost.
Critical This event is generated when redundancy is
lost in a spared memory conguration.
Memory Spared redundancy
regained.
Information This event is generated when the
redundancy lost or degraded earlier is
regained in a spared memory conguration.
Memory RAID is redundant.
Information This event is generated when the memory
redundancy mode has change to RAID
redundant.
Memory RAID redundancy is
lost. Check memory device at
location(s) <DIMM number>.
Critical This event is generated when redundancy is
lost in a RAID-congured memory
conguration.
Memory RAID redundancy is
degraded. Check memory device
at location(s) <DIMM number >.
Warning This event is generated when there is a
memory failure in a RAID-congured
memory conguration.
Memory is not redundant.
Information This event is generated when the memory
redundancy mode has change to
nonredundant.
Memory mirror is redundant.
Information This event is generated when the memory
redundancy mode has change to mirror
redundant.
Memory mirror redundancy is
lost. Check memory device at
location(s) <DIMM number>.
Critical This event is generated when redundancy is
lost in a mirror-congured memory
conguration.
Memory mirror redundancy is
degraded. Check memory device
at location <DIMM number >.
Warning This event is generated when there is a
memory failure in a mirror-congured
memory conguration.
Memory spare is redundant.
Information This event is generated when the memory
redundancy mode has change to spare
redundant.
Memory spare redundancy is
lost. Check memory device at
location <DIMM number>.
Critical This event is generated when redundancy is
lost in a sparer-congured memory
conguration.
Memory spare redundancy is
degraded. Check memory device
at location <DIMM number>.
Warning This event is generated when there is a
memory failure in a spare-congured
memory conguration.
System Event Log Messages for IPMI Systems 225