Reference Guide
Event Message Severity Cause
Fan failure detected on power
supply <number>.
Critical The specied power supply fan has failed.
Communication has been
restored to power supply
<number>.
Information This event is generated when the power
supply has recovered from an earlier
communication problem.
A power supply wattage
mismatch is detected; power
supply <number> is rated for
<value> watts.
Critical This event is generated when there is more
than one power supplies in the system and
the power supply wattage do not match.
Power supply <number> wattage
mismatch corrected.
Information This event is generated when the power
supply has recovered from an earlier power
supply wattage mismatch.
Power supply redundancy is
lost.
Critical Power supply redundancy is lost if only one
power supply is functional.
Power supply redundancy is
degraded.
Warning Power supply redundancy is degraded if one
of the power supply sources is removed or
failed.
The power supplies are
redundant.
Information This event is generated if the power supply
has been reconnected or replaced.
Memory ECC Events
The memory ECC event messages monitor the memory modules in a system. These messages monitor the ECC memory correction rate
and the type of memory events that occurred.
Table 10. Memory ECC Events
E
v
e
n
t
M
e
s
s
a
g
e
Severity Cause
Information This event is generated when
there is a memory error correction
on a particular Dual Inline Memory
Module (DIMM).
Critical This event is generated when the
chipset is unable to correct the
memory errors. Usually, a bank
number is provided and DIMM
may or may not be identiable,
depending on the error.
222 System Event Log Messages for IPMI Systems