Reference Guide
Event Message Severity Cause
PS 1 Status: Power supply
sensor for PS 1, configuration
error was asserted.
Warning/Critical This event is generated when an invalid
power supply conguration is detected.
PS 1 Status: Power supply
sensor for PS 1, configuration
error was deasserted.
Information This event is generated when the power
supply has recovered from an earlier invalid
conguration.
Power supply <number> is
present.
Information This event is generated when the power
supply is plugged in.
Power supply <number> is
absent.
Critical This event is generated when the power
supply is removed.
Power supply <number> failed.
Critical This event is generated when the power
supply has failed.
A predictive failure detected
on power supply <number>.
Warning This event is generated when the power
supply is about to fail.
The power input for power
supply <number> is lost.
Critical This event is generated when input power is
removed from the power supply.
The input power for power
supply <number> has been
restored.
Information This event is generated if the power supply
has been reconnected or replaced.
Power supply <number> is
incorrectly configured.
Critical/Warning This event is generated when an invalid
power supply conguration is detected.
Power supply <number> is
correctly configured.
Information This event is generated when the power
supply has recovered from an earlier invalid
conguration.
Power supply <number> is
operating normally.
Information This event is generated when the power
supply has recovered from an earlier failure
event.
Cannot communicate with power
supply <number>.
Critical The power supply may operate, however
power supply monitoring is degraded.
The temperature for power
supply <number> is in a
warning range.
Warning Temperature of specied power supply
entered into non-critical state.
The temperature for power
supply <number> is outside of
range.
Critical Temperature of specied power supply
entered into critical state.
An under voltage fault
detected on power supply
<number>.
Critical The specied power supply detected
inecient voltage.
An over voltage fault detected
on power supply <number>.
Critical The specied power supply detected an
over voltage condition.
An over current fault detected
on power supply <number>.
Crotoca; The specied power supply detected an
over current condition.
System Event Log Messages for IPMI Systems 221