Reference Guide
Event Message Severity Cause
<Power Supply Sensor Name>
power supply sensor returned
to normal state.
Information This event is generated when the power
supply that failed or removed was replaced
and the state has returned to normal.
<Entity Name> PS Redundancy
sensor redundancy degraded.
Information Power supply redundancy is degraded if one
of the power supply sources is removed or
failed.
<Entity Name> PS Redundancy
sensor redundancy lost.
Critical Power supply redundancy is lost if only one
power supply is functional.
<Entity Name> PS Redundancy
sensor redundancy regained.
Information This event is generated if the power supply
has been reconnected or replaced.
<Power Supply Sensor Name>
predictive failure was
asserted.
Critical This event is generated when the power
supply is about to fail.
<Power Supply Sensor Name>
input lost was asserted.
Critical This event is generated when the power
supply is unplugged.
<Power Supply Sensor Name>
predictive failure was
deasserted.
Information This event is generated when the power
supply has recovered from an earlier
predictive failure event.
<Power Supply Sensor Name>
input lost was deasserted.
Information This event is generated when the power
supply is plugged in.
PS 1 Status: Power supply
sensor for PS 1, presence was
asserted.
Information This event is generated when the power
supply is plugged in.
PS 1 Status: Power supply
sensor for PS 1, presence was
deasserted.
Critical This event is generated when the power
supply is removed.
PS 1 Status: Power supply
sensor for PS 1, failure was
asserted.
Critical This event is generated when the power
supply has failed.
PS 1 Status: Power supply
sensor for PS 1, failure was
deasserted.
Information This event is generated when the power
supply has recovered from an earlier failure
event.
PS 1 Status: Power supply
sensor for PS 1, predictive
failure was asserted.
Warning This event is generated when the power
supply is about to fail.
PS 1 Status: Power supply
sensor for PS 1, predictive
failure was deasserted.
Information This event is generated when the power
supply has recovered from an earlier
predictive failure event.
PS 1 Status: Power supply
sensor for PS 1, input lost
was asserted.
Critical This event is generated when AC power is
removed from the power supply.
PS 1 Status: Power supply
sensor for PS 1, input lost
was deasserted.
Information This event is generated when the power
supply is plugged in.
220 System Event Log Messages for IPMI Systems