Reference Guide

Event Message Severity Cause
<Processor Entity>
configuration error was
deasserted.
Information This event is generated when the earlier
processor conguration error was corrected.
<Processor Entity> throttled
was asserted.
Warning This event is generated when the processor
slows down to prevent overheating.
<Processor Entity> throttled
was deasserted.
Information This event is generated when the earlier
processor throttled event was corrected.
CPU <number> has an internal
error (IERR).
Critical The specied CPU generated an internal
error.
CPU <number> has a thermal
trip (over-temperature) event.
Critical The CPU generates this event before it
shuts down because of excessive heat
caused by lack of cooling or heat
synchronization.
CPU <number> configuration is
unsupported.
Warning The specied CPU is not support for this
system.
CPU <number> is present.
Information The specied CPU is present.
CPU <number> terminator is
present.
Information This event is generated if the terminator is
present on a processor slot.
CPU <number> terminator is
absent.
Warning This event is generated if the terminator is
missing on an empty processor slot.
CPU <number> is throttled.
Warning This event is generated when the processor
slows down to prevent overheating.
CPU <number> is absent.
Critical This event is generated when the system
could not detect the processor.
CPU <number> is operating
correctly.
Information This event is generated when the processor
recovered from an error.
CPU <number> is configured
correctly.
Information The specied CPU is congured correctly.
Power Supply Events
The power supply sensors monitor the functionality of the power supplies. These messages provide status and warning information for
power supplies for a particular system.
Table 9. Power Supply Events
Event Message Severity Cause
<Power Supply Sensor Name>
power supply sensor removed.
Critical This event is generated when the power
supply sensor is removed.
<Power Supply Sensor Name>
power supply sensor AC
recovered.
Information This event is generated when the power
supply has been replaced.
System Event Log Messages for IPMI Systems 219