Reference Guide

Severity Warning / Non-critical
Cause and Action Cause: The physical disk is using an incompatible technology.
Action: All physical disks in the virtual disk must use the same technology. You cannot use both SAS and SATA
physical disks in the same virtual disk. Remove the physical disk and insert a new physical disk that uses the
correct technology. If the rebuild does not start automatically after you have inserted a suitable physical disk, then
run the Rebuild task.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2326
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
Event ID — 2368
Description The SCSI Enclosure Processor (SEP) has been rebooted as part of the rmware download operation and is
unavailable until the operation completes.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2049, 2052, 2162, 2292
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
851
Event ID — 2369
Description
Virtual Disk Redundancy has been degraded.
Severity OK / Normal / Informational
Cause and Action Cause: A physical disk in a RAID 6 virtual disk has either failed or been removed.
Action: Replace the missing or failed physical disk.
Related Alert
Information
Clear Alert Number: 2121
Related Alert Number: 2048, 2049, 2050, 2076, 2346
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1201
Storage Management Message Reference 173