Reference Guide
Event ID — 2357
Description SAS expander error: %1.
Severity Critical / Failure / Error
Cause and Action Cause: The %1 indicates a substitution variable. The text for this substitution variable is generated by the rmware
and is displayed with the alert in the alert log. This text can vary depending on the situation.
Action: There may be a problem with the enclosure. Check the health of the enclosure and its components by
selecting the enclosure object in the tree view. The Health subtab displays a red X or yellow exclamation point for
enclosure components that are Failed or Degraded. See the enclosure documentation for more information.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2061
SNMP Trap
Numbers
754
Event ID — 2358
Description
The battery charge cycle is complete.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1151
Event ID — 2359
Description
Disk found is not supplied by an authorized hardware provider.
Severity Warning / Non-critical
Cause and Action Cause: The physical disk does not comply with the standards set and is not supported.
Action: Replace the physical disk with a physical disk that is supported.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
170 Storage Management Message Reference