Reference Guide

Event ID — 2347
Description The rebuild failed due to errors on the source physical disk.
Severity Critical / Failure / Error
Cause and Action Hardware RAID: Cause and Action
Cause: You are attempting to rebuild data that resides on a defective disk.
Action: Replace the source disk and restore from backup.
Software RAID:
Perform a backup with the Verify option.
If the le backup fails, try to restore the failed le from a previous backup.
When the backup with the Verify option is complete without any errors, delete the Virtual Disk.
Recreate a new Virtual Disk with new drives.
Restore the data from backup.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2195, 2346
Local Response Agent (LRA) Number: 2071
SNMP Trap
Numbers
904
Event ID — 2348
Description
The rebuild failed due to errors on the target physical disk.
Severity Critical / Failure / Error
Cause and Action Cause:You are attempting to rebuild data on a disk that is defective.
Action: Replace the target disk. If a rebuild does not automatically start after replacing the disk, initiate the Rebuild
task. You may need to assign the new disk as a hot spare to initiate the rebuild.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2195, 2346
Local Response Agent (LRA) Number: 2071
SNMP Trap
Numbers
904
Event ID — 2349
Description
A bad disk block could not be reassigned during a write operation.
166 Storage Management Message Reference