Reference Guide
Event ID — 2342
Description The Check Consistency found inconsistent parity data. Data redundancy may be lost.
Severity Warning / Non-critical
Cause and Action Cause: The data on a source disk and the redundant data on a target disk is inconsistent.
Action: Restart the Check Consistency task. If you receive this alert again, check the health of the physical disks
included in the virtual disk. Review the alert messages for signicant alerts related to the physical disks. If you
suspect that a physical disk has a problem, replace it and restore from backup.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2341, 2343
Local Response Agent (LRA) Number: 2080
SNMP Trap
Numbers
1203
Event ID — 2343
Description
The Check Consistency logging of inconsistent parity data is disabled.
Severity Warning / Non-critical
Cause and Action Cause: The Check Consistency can no longer report errors in the parity data.
Action: See the hardware documentation for more information.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2080
SNMP Trap
Numbers
1203
Event ID — 2344
Description
The virtual disk initialization terminated.
Severity Warning / Non-critical
Cause and Action Cause: A user has cancelled the virtual disk initialization.
Action: Restart the initialization.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
164 Storage Management Message Reference