Reference Guide
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
751
Event ID — 2340
Description The BGI completed with uncorrectable errors.
Severity Critical / Failure / Error
Cause and Action Cause: The BGI task encountered errors that cannot be corrected. The virtual disk contains physical disks that
have unusable disk space or disk errors that cannot be corrected.
Action: Replace the physical disk that contains the disk errors. Review other alert messages to identify the physical
disk that has errors. If the virtual disk is redundant, you can replace the physical disk and continue using the virtual
disk. If the virtual disk is non-redundant, you may need to recreate the virtual disk after replacing the physical disk.
After replacing the physical disk, run Check Consistency to check the data.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2081
SNMP Trap
Numbers
1204
Event ID — 2341
Description
The Check Consistency made corrections and completed.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1201