Reference Guide
Event ID — 2314
Description The initialization sequence of SAS components failed during system startup. SAS management and monitoring is
not possible.
Severity Critical / Failure / Error
Cause and Action Cause: Storage Management is unable to monitor or manage SAS devices.
Action: Reboot the system. If problem persists, make sure you have supported versions of the drivers and
rmware. Also, you may need to reinstall Storage Management or Server Administrator because of some missing
installation components.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2051
SNMP Trap
Numbers
104
Event Id — 2315
Description
Diagnostic message %1
Severity OK / Normal / Informational
Cause and Action Cause: The %1 indicates a substitution variable. The text for this substitution variable is generated by the utility
that ran the diagnostics and is displayed with the alert in the alert log. This text can vary depending on the
situation. This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
751
Event ID — 2316
Description
Diagnostic message %1
Severity Critical / Failure / Error
Cause and Action Cause: A diagnostics test failed. The %1 indicates a substitution variable. The text for this substitution variable is
generated by the utility that ran the diagnostics and is displayed with the alert in the alert log. This text can vary
depending on the situation.
154 Storage Management Message Reference