Reference Guide
Event ID — 2273
Description A block on the physical disk has been punctured by the controller.
Severity Critical / Failure / Error
Cause and Action Cause: The controller encountered an unrecoverable medium error when attempting to read a block on the
physical disk and marked that block as invalid. If the error was encountered on a source physical disk during a
rebuild or recongure operation, it also punctures the corresponding block on the target physical disk. The invalid
block is cleared during a write operation.
Action: Back up your data. If you are able to back up the data successfully, initialize the disk and restore from the
back up.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2095, 2350
Local Response Agent (LRA) Number: 2071
SNMP Trap
Numbers
904
Event ID — 2274
Description
The physical disk rebuild has resumed.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
901
Event ID — 2276
Description
The dedicated hot spare is too small.
Severity Warning / Non-critical
Cause and Action Cause: The dedicated hot spare is not large enough to protect all virtual disks that reside on the disk group.
Action: Assign a larger disk as the dedicated hot spare.