Reference Guide

Event ID — 2268
Description %1, Storage Management has lost communication with the controller. An immediate reboot is strongly
recommended to avoid further problems. If the reboot does not restore communication, then contact technical
support for more information.
Severity Critical / Failure / Error
Cause and Action Cause: Storage Management has lost communication with a controller. This may occur if the controller driver or
rmware is experiencing a problem. The %1 indicates a substitution variable. The text for this substitution variable
is displayed with the alert in the alert log and can vary depending on the situation.
Action: Reboot the system. If the problem is not resolved, contact technical support. See your system
documentation for information about contacting technical support by using telephone, fax, and Internet services.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2051
SNMP Trap
Numbers
104
Event ID — 2269
Description
The physical disk Clear operation has completed.
Severity OK / Normal / Informational
Cause and Action
Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
901
Event ID — 2270
Description
The physical disk Clear operation failed.
Severity Critical / Failure / Error
Cause and Action Cause: A Clear task was being performed on a physical disk but the task was interrupted and did not complete
successfully. The controller may have lost communication with the disk. The disk may have been removed or the
cables may be loose or defective.
Storage Management Message Reference 137