Reference Guide
Event ID — 2263
Description SMART thermal shutdown is disabled.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
101
Event ID — 2264
Description A device is missing.
Severity Warning / Non-critical
Cause and Action Cause: The controller cannot communicate with a device. The device may be removed. There may also be a bad or
loose cable.
Action: Check if the device is in and not removed. If it is in, check the cables. Also check the connection to the
controller battery and the battery health. A battery with a weak or depleted charge may cause this alert.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2050, 2060, 2070, 2080, 2090, 2100
SNMP Trap
Numbers
753, 803, 853, 903, 953, 1003, 1053, 1103, 1153, 1203
Event ID — 2265
Description
A device is in an unknown state.
Severity Warning / Non-critical
Cause and Action Cause: The controller cannot communicate with a device. The state of the device cannot be determined. There
may be a bad or loose cable. The system may also be experiencing problems with the application programming
interface (API). There could also be a problem with the driver or rmware.
Action: Check the cables. Check if the controller has a supported version of the driver and rmware. You can
download the current version of the driver and rmware from the support site. Rebooting the system may also
resolve this problem.
Storage Management Message Reference 135