Reference Guide
Event ID — 2211
Description The physical disk is not supported.
Severity Warning / Non-critical
Cause and Action Cause: The physical disk may not have a supported version of the rmware or the disk may not be supported by
your service provider.
Action: If the disk is supported, update the rmware to a supported version. If the disk is not supported by your
service provider, replace the disk with one that is supported.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
Event ID — 2212
Description
The controller battery temperature is above normal.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1151
Event ID — 2213
Description
Recharge count maximum exceeded.
Severity Warning / Non-critical
Cause and Action Cause: The battery has been recharged more times than the battery recharge limit allows.
Action: Replace the battery pack.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Storage Management Message Reference 117