Reference Guide
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2090
SNMP Trap
Numbers
853
Event ID — 2174
Description The controller battery has been removed.
Severity Warning / Non-critical
Cause and Action Cause: The controller cannot communicate with the battery. The battery may be removed, or the contact point
between the controller and the battery may be burnt or corroded.
Action: Replace the battery if it has been removed. If the contact point between the battery and the controller is
burnt or corroded, you must replace either the battery or the controller, or both. See the hardware documentation
for information on how to safely access, remove, and replace the battery.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2188, 2318
Local Response Agent (LRA) Number: 2100
SNMP Trap
Numbers
1153
Event ID — 2175
Description
The controller battery has been replaced.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1151
Event ID — 2176
Description
The controller battery Learn cycle has started.
104 Storage Management Message Reference