Reference Guide
Cause and Action Cause: The version of the driver does not meet the minimum requirements. Storage Management may not be able
to display the storage or perform storage management functions until you have updated the system to meet the
minimum requirements.
Action: See the Readme ξle for the validated driver version. Update the system to meet the minimum
requirements and then reinstall Storage Management.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2050
SNMP Trap
Numbers
103
Event ID β 2169
Description The controller battery needs to be replaced.
Severity Critical / Failure / Error
Cause and Action Cause: The controller battery cannot be recharged. The battery may be old or it may have been already recharged
the maximum number of times. In addition, the battery charger may not be working.
Action: Replace the battery pack.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2118
Local Response Agent (LRA) Number: 2101
SNMP Trap
Numbers
1154
Event ID β 2170
Description
The controller battery charge level is normal.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1151
102 Storage Management Message Reference