Reference Guide

Event ID — 2166
Description The RAID controller rmware and driver validation was not performed. The conguration le is out of date, missing
the required information, or not properly formatted to complete the comparison.
Severity Warning / Non-critical
Cause and Action Cause: Storage Management is unable to determine whether the system has the minimum required versions of the
RAID controller rmware and drivers. This situation has occurred because a conguration le is out of date, missing
the required information, or not properly formatted to complete the comparison.
Action: Reinstall Storage Management.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2060
SNMP Trap
Numbers
753
Event ID — 2167
Description
The current kernel version and the non-RAID SCSI driver version are older than the minimum required levels. See
readme.txt for a list of validated kernel and driver versions.
Severity Warning / Non-critical
Cause and Action Cause: The version of the kernel and the driver do not meet the minimum requirements. Storage Management may
not be able to display the storage or perform storage management functions until you have updated the system to
meet the minimum requirements.
Action: See the Readme le for a list of validated kernel and driver versions. Update the system to meet the
minimum requirements and then reinstall Storage Management.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2050
SNMP Trap
Numbers
103
Event ID — 2168
Description
The non-RAID SCSI driver version is older than the minimum required level. See readme.txt for the validated driver
version.
Severity Warning / Non-critical
Storage Management Message Reference 101