Release Notes
• omcong rac uploadcert
• omcong rac generatecert
The following racadm commands use FTP protocol to communicate with the RAC:
• racadm sslcertupload
• racadm sslcsrgen
• racadm fwupdate
• If the RAC conguration is reset to factory defaults using the racadm racresetcfg command, the RAC conguration tab in Server
Administrator does not reect the reset conguration settings until the system reboots. Also, the RAC conguration page in Server
Administrator cannot be used to make any conguration changes until the system reboots.
• The RAC does not support local RAC user IDs with special characters. When adding a local RAC user, use only alphanumeric characters
for the user name.
• While the RAC is being reset, the Instrumentation Service cannot read sensor data for certain systems. As a result, the voltage,
temperature, and other probes may not be visible on the Server Administrator home page until the RAC has completed resetting.
• The RAC may not send traps when your system is locked up. To enable traps to be sent when the system is locked, congure the
watchdog timer using the Server Administrator GUI. On the GUI, click the "Properties" tab and ensure that Auto Recovery is selected.
The default value of theAction On Hung Operating System Detection setting is None.None indicates that detection will not be
performed.
• RAC rmware 2.0 and later does not support passwords with special characters (non- alphanumeric) only for RAC user IDs logging in
using the Web-based interface (with Local RAC Authentication). You cannot log on to RAC, if you created RAC user IDs using previous
versions of the rmware or using Server Administrator that is running version 2.0 rmware on the managed system.
Use one of these methods to correct this issue:
• Change your passwords before updating the rmware.
• Use the following CLI command to change the password: omcong rac users username=xx userpassword=yy where xx is the
original user ID and yy is the new password.
• Change the password through Server Administrator using the User tab. Make sure that the check box to change the password is
checked. Enter a new password, and then enter it again to validate the change.
• Use the racadm utility to change the password: racadm cong -g cfgUserAdmin -o cfgUserAdminPassword -i <usr_index>
<new_pwd> where <usr_index> is the index of the user database entry to be modied and <new_pwd> is the new password.
• Depending on your network and proxy congurations and whether you are using Mozilla browser, you may need to enter the exact IP
address of the RAC controller, you are trying to access in the No Proxy for eld of your browser.
Perform the following steps:
a Open your Mozilla browser.
b Click Edit.
c Click Preferences.
d Click Advanced in the left sidebar.
e Click Proxies in the left sidebar.
f Enter the RAC IP address in the No Proxy for: eld.
g Click OK and then close the browser.
• To view the RAC Web-based interface when using Mozilla 1.6, you must congure your cookie settings to Enable all cookies.
• To enable all cookies, go to the menu options and click Edit > Preferences > Privacy & Security > Cookies, and then select Enable all
cookies. If you do not perform these steps, you cannot log on to the Web interface and a message appears indicating that your
username and password are incorrect.
• DF384362: Redundancy Status displays as Not Applicable in ESXi even when NICs are teamed. On VMware ESXi systems, NIC
teaming status may not display up in the Server Administrator network section. This is an expected behavior due to the operating
system limitation and has no functional impact to the system.
• DF384061: Self-signed certicate does not enable the compatibility listener in Windows 2008 R2 managed node. On a Windows 2008
R2 managed node, a valid CA signed certicate is required to create compatibility mode WinRM Listener. You cannot create a
compatibility mode listener with a self-signed certicate.
• DF380725: On Internet Explorer or Firefox Web browsers, you cannot attach les to an e- mail if the lename contains non-ASCII
letters. To attach les to an e-mail, rename les to contain ASCII characters.