Release Notes
• Delete the keystore.db le at /opt/dell/srvadmin/lib64/openmanage/apache- tomcat/conf
• Rename the keystore.db.bak at /opt/dell/srvadmin/lib64/openmanage/apache-tomcat/conf to keystore.db
c Start the Web server.
• BITS078118: On 12th generation of PowerEdge servers with specic versions of iDRAC, you cannot set the platform event alert actions
(reboot, shut down, and so on) through Server Administrator. Set the alert actions for the events through iDRAC GUI.
• BITS144583: On Mozilla Firefox 21 or later, the Quit browser option does not work after logging out from Server Administrator. To
close the browser or tab, you must manually close the Firefox browser tab.
• BITS177670: On Chrome 38 or later, the Quit browser option does not work after logging out from Server Administrator. To close the
browser or tab, you must manually close the Firefox browser tab.
• On PowerEdge T430, C4130, and R220 II, with PERC S130 conguration and no backplane, Storage Management displays a mock
backplane which does not support the blink/unblink operation for disks available on this conguration.
• BITS256932: The default factory IP for an IDRAC is “192.168.0.120” or “192.168.0.*”, which indicates that the iDRAC IP is not congured
by the user. However, if you choose to congure the default factory IP (static or DHCP) as your iDRAC IP, then the “Not Congured”
value for “iDRAC Network Settings” displayed on the OMSA “System Summary” page can be ignored. Note: On rack and tower
systems, the default factory IP for iDRAC is “192.168.0.120”. On modular systems, the default factory IP range for iDRAC is “192.168.0.*”,
where “*” can be any value from 0 to 255.
• BITS265922: The DSM SA Connection will fail to start if Java Runtime Engine 1.8.0 or newer is installed and specied as the “System
JRE” in Preferences of the Server Administrator web GUI. OMSA 8.3 and older is currently not compatible with Java 1.8 or newer. To
recover to the default Bundled JRE setting so that the web service starts again, enter the following command line: omcong
preferences webserver attribute=setjre jreversion=bundled
• BITS260330/BITS260451:Restart the data manager service, after Intel NIC driver update or NVIDIA graphics driver update is
performed.
• JIT-25314: The alert log is not generated in Server Administrator, when the Power Supply Unit (PSU) is inserted in the server without
connecting a power cable for that PSU. However, corresponding log is generated in ESM or Hardware logs.
• JIT-22805: Server Administrator does not recommend the upgrade to major versions of JRE. For more details, see the release notes of
Server Administrator (packaged with Server Administrator application) or at dell.com/openmanagemanuals.
• JIT-31814: OpenManage Server Administrator Cannot show the SNMP test trap destination addresses, when admin congured
through domain policy.
• JIT-36610/JIT-36599: In OpenManage Server Administrator slots page, the Dell “HBA330 Adapter” PERC card will be enumerated as
“12GB/s HBA internal” and Dell “HBA330 Mini” PERC card will be enumerated as “SAS3008 PCI-Express Fusion-MPT SAS-3
Issues for Remote Access
NOTE
: The Remote Access Service is supported on 11th generation of PowerEdge servers only. The following subsections list the
currently known issues regarding implementation and operation of your RAC and the Remote Access Service in Server
Administrator.
Issues of Server Administrator on all Operating Systems
• The Server Administrator user interface and commands related to local authentication enable are not applicable for RAC rmware
3.20. The Active Directory authentication feature replaces the local operating system authentication feature in this version of
rmware. Due to this change, the following commands return errors:
• racadm localauthenable
• omcong rac authentication
• Due to uctuations in the watchdog timer, the Last Crash Screen may not be captured when the Automatic System Recovery is set to
a value of less than 30 seconds. To ensure the correct functioning of the Last Crash Screen feature, set the System Reset Timer to at
least 30 seconds.
• DF132894: The cfgDNSServer1 and cfgDNSServer2 properties of group cfgLanNetworking may be set to identical values while
swapping addresses. Some performance may be lost temporarily during the swapping. The cfgLanNetworking group is congured using
theracadm cong command.
• The remote access controller uses FTP protocol to perform some of the Server Administrator commands. If a rewall is installed in the
system, it may cause these commands to fail.
The following Server Administrator CLI commands use FTP protocol to communicate with the RAC:
12
Dell EMC OpenManage Release Notes
Version 9.0.2