TrapID Description Category SubCategory Severity
4178 Storage Management has detected a
device independent warning condition.
There is no global status change
associated with this trap.
Storage Storage Minor
Storage Management Failure
4177 Storage Management has detected a
device independent error condition.
There is no global status change
associated with this trap.
Storage Storage Critical
Table 420. Temperature Probe Traps
TrapID Description Category SubCategory Severity
Storage Temperature Probe Information
4211 Temperature probe information. Storage Temperature Informational
Storage Temperature Probe Warning
4210 Temperature probe warning. Storage Temperature Minor
Storage Temperature Probe Failure
4209 Temperature probe failure. Storage Temperature Critical
Table 421. Virtual Disk Trap
TrapID Description Category SubCategory Severity
Storage VirtualDisk Information
4355 Virtual disk information. Storage Virtual Disk Informational
Storage Virtual Disk Warning
4354 Virtual disk warning. Storage Virtual Disk Minor
Storage Virtual Disk Failure
4353 Virtual disk failure. Storage Virtual Disk Critical
Updates Trap Group
The Updates Trap Group contains traps that fall under the Updates event category of iDRAC. Updates traps are traps generated in
response to events related to firmware/driver upgrades/downgrades.
Table 422. Update Traps
TrapID Description Category SubCategory Severity
Updates Trap Information
6211 Update job information. Updates Updates Informational
Table 423. Software Change Traps
TrapID Description Category SubCategory Severity
Software Change Update Warning
6314 Software change update warning. Updates Software Change Minor
Audit Trap Group
The Audit Trap Group contains traps that fall under the Audit event category of iDRAC8. Audit traps are traps generated in response to
audit-type events of iDRAC8, such as authorizing of debugging, changes to iDRAC8 license state, power state changes, etc.
iDRAC MIB