Connectivity Guide

TrapID Description Severity
1076996 System Event Log (SEL) Full (Logging
Disabled)
Critical
2322176 ASR (Automatic System Recovery) Timer
Expired
Critical
2322177 ASR (Automatic System Recovery) Reset
Occurred
Critical
2322178 ASR (Automatic System Recovery) Power
Down Occurred
Critical
2322179 ASR (Automatic System Recovery) Power
Cycle Occurred
Critical
PowerEdge M1000e CMC Traps
This section describes the traps that are generated by the SNMP agent of the PowerEdge M1000e CMC. All of the enterprise-specific
traps documented in this section belong to the MIB enterprise identified by OID 1.3.6.1.4.1.674.10892.2 and are sent with the following trap
variables: drsProductChassisName, drsProductChassisLocation, drsGlobalCurrStatus, drsCASubSystem, drsCASSCurrStatus,
drsCASSPrevStatus, drsCASSChangeTime and drsCAMessage.
PowerEdge M1000e CMC version 5.0 and later supports a setting to generate the traps listed in the section "PowerEdge VRTX CMC
Traps and PowerEdge FX2 CMC Traps". The setting is named "Enable Enhanced Chassis Logging and Events" in the PowerEdge M1000e
CMC GUI and is located in the General Chassis Settings page which can be found by navigating to Chassis Overview -> Setup -> General
in the CMC GUI. When the setting is disabled, the traps listed in this section are generated by the CMC. When the setting is enabled, the
traps listed in the section "PowerEdge VRTX CMC Traps and PowerEdge FX2 CMC Traps" are generated by the CMC instead of the
traps listed in this section. The setting is disabled by default. The trap variables are defined in the
Dell Remote Access Controller Out-of-
Band Group section.
Table 125. PowerEdge M1000e CMC traps
TrapID Name Description Severity Category
2000 alertCMCTestTrap CMC has generated a test trap. Informational Error Events
2002 alertCMCNormalTrap CMC reported a return-to-
normal or informational event.
Normal Error Events
2003 alertCMCWarningTrap CMC reported a warning event. Warning Error Events
2004 alertCMCCriticalTrap CMC reported a critical event. Critical Error Events
2005 alertCMCNonRecoverableT
rap
CMC reported a catastrophic
event.
Non-Recoverable Error Events
PowerEdge VRTX CMC Traps and PowerEdge FX2
CMC Traps
This section defines the traps that are generated by the SNMP agent of the PowerEdge VRTX CMC and PowerEdge FX2 CMC. All of the
enterprise-specific traps documented in this section belong to the MIB enterprise identified by OID 1.3.6.1.4.1.674.10892.2.21 and are sent
with the following trap variables: drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD,
drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag and drsGlobalCurrStatus. The trap variables are defined in
the
Dell Remote Access Controller Out-of-Band Group section.
System Trap Group
The System Trap Group contains traps that fall under the System event category.
Table 126. Amperage Probe Traps
TrapID Description Category SubCategory Severity
alert2AmperageProbeNormal
SNMP Traps 33