Reference Guide
Cause and Action Cause: Storage Management is unable to determine whether the system has the minimum required versions
of the RAID controller drivers. This alert is for informational purposes.
Action: See the Readme le for driver and rmware requirements. In particular, if Storage Management
experiences performance problems, you should verify that you have the minimum supported versions of the
drivers and rmware installed.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
101
Event ID — 2165
Description The RAID controller rmware and driver validation was not performed. The conguration le cannot be
opened.
Severity Warning / Non-critical
Cause and Action Cause: Storage Management is unable to determine whether the system has the minimum required versions
of the RAID controller rmware and drivers. This situation may occur for a variety of reasons. For example,
the installation directory path to the conguration le may not be correct. The conguration le may also
have been removed or renamed.
Action: Reinstall Storage Management
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2060
SNMP Trap
Numbers
753
Event ID — 2166
Description
The RAID controller rmware and driver validation was not performed. The conguration le is out of date,
missing the required information, or not properly formatted to complete the comparison.
Severity Warning / Non-critical
Cause and Action Cause: Storage Management is unable to determine whether the system has the minimum required versions
of the RAID controller rmware and drivers. This situation has occurred because a conguration le is out of
date, missing the required information, or not properly formatted to complete the comparison.
Action: Reinstall Storage Management.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2060
90