Reference Guide

NOTE: A critical status does not always indicate a system failure or loss of data. In some instances, the system has
exceeded the ECC correction rate. Although the system continues to function, you should perform system maintenance
as described.
NOTE: The <status> can be either critical or non-critical.
Event ID — 1400
Description
Memory device status is <status>
Memory device location: <location in chassis>
Possible memory module event cause: <list of causes>
Severity Informational
Cause Memory device monitoring has been disabled. The memory module may not be correctly seated, wrongly
congured, or has failed.
Event ID — 1401
Description
Memory device status is <status>
Memory device location: <location in chassis>
Possible memory module event cause: <list of causes>
Severity Informational
Cause Memory device status is unknown. The memory module may not be correctly seated, wrongly congured, or
has failed.
Event ID — 1402
Description
Memory device status is <status>
Memory device location: <location in chassis>
Possible memory module event cause: <list of causes>
Severity Informational
Cause Memory device status is normal. The memory device identied in the message has returned to a normal
state.
Event ID — 1403
Description
Memory device status is <status>
Memory device location: <location in chassis>
Possible memory module event cause: <list of causes>
Severity Warning
Cause A memory device correction rate exceeded an acceptable value. The memory device status and possible
memory module event cause information is provided.
42