Reference Guide

Related Alert Number: None
Local Response Agent (LRA) Number: 2090
SNMP Trap
Numbers
853
Event ID — 2299
Description Bad PHY %1
Severity Critical / Failure / Error
Cause and Action Cause: There is a problem with a physical connection or PHY. The %1 indicates a substitution variable. The
text for this substitution variable is displayed with the alert in the alert log and can vary depending on the
situation.
Action: Contact your technical support.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2091
SNMP Trap
Numbers
854
Event ID — 2300
Description
The enclosure is unstable.
Severity Critical / Failure / Error
Cause and Action Cause: The controller is not receiving a consistent response from the enclosure. There could be a rmware
problem or an invalid cabling conguration. If the cables are too long, they degrade the signal.
Action: Power down all enclosures attached to the system and reboot the system. If the problem persists,
upgrade the rmware to the latest supported version. You can download the most current version of the
driver and rmware from the support site. Make sure the cable conguration is valid. See the hardware
documentation for valid cabling congurations.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2091
SNMP Trap
Numbers
854
Event ID — 2301
Description
The enclosure has a hardware error.
Severity Critical / Failure / Error
Cause and Action Cause: The enclosure or an enclosure component is in a Failed or Degraded state.
134