Reference Guide
Related Alert Number: None
Local Response Agent (LRA) Number: 2090
SNMP Trap
Numbers
853
Event ID — 2299
Description Bad PHY %1
Severity Critical / Failure / Error
Cause and Action Cause: There is a problem with a physical connection or PHY. The %1 indicates a substitution variable. The
text for this substitution variable is displayed with the alert in the alert log and can vary depending on the
situation.
Action: Contact your technical support.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2091
SNMP Trap
Numbers
854
Event ID — 2300
Description
The enclosure is unstable.
Severity Critical / Failure / Error
Cause and Action Cause: The controller is not receiving a consistent response from the enclosure. There could be a rmware
problem or an invalid cabling conguration. If the cables are too long, they degrade the signal.
Action: Power down all enclosures attached to the system and reboot the system. If the problem persists,
upgrade the rmware to the latest supported version. You can download the most current version of the
driver and rmware from the support site. Make sure the cable conguration is valid. See the hardware
documentation for valid cabling congurations.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2091
SNMP Trap
Numbers
854
Event ID — 2301
Description
The enclosure has a hardware error.
Severity Critical / Failure / Error
Cause and Action Cause: The enclosure or an enclosure component is in a Failed or Degraded state.
134