Reference Guide
Table Of Contents
- Dell EMC OpenManage SNMP Reference Guide Version 10.1.0.0
- Contents
- Introduction
- What is new in this release
- Supported SNMP Versions
- Managed Object Used in This Document
- Server Administrator Instrumentation MIB
- Server Administrator Baseboard Management Controller, ASF MIB
- Server Administrator Storage Management MIB
- Server Administrator Field Replaceable Unit MIB
- Server Administrator Change Management MIB
- Basic Terminology
- Frequently Used Terms in Variable Names
- Tables
- Section Organization
- Other Documents You May Need
- Introduction to the Server Administrator SNMP Subagent
- System Battery Table
- Amperage Probe Table
- Power Unit Group
- Power Supply Table
- Power Usage Table
- Voltage Probe Table
- System Information Group
- Server Administrator Group
- Instrumentation MIB Version Group
- Systems Management Software Group
- System State Group
- Chassis Information Group
- Operating System Group
- System Resource Group
- Power Group
- Thermal Group
- Remote Flash BIOS Group
- Port Group
- Device Group
- Device Tables
- Pointing Device Table
- Keyboard Device Table
- Processor Device Table
- Processor Device Status Table
- Cache Device Table
- Memory Device Table
- Memory Device Mapped Address Table
- Generic Device Table
- PCI Device Table
- PCI Device Configuration Space Table
- Network Device Table
- Managed System Services Device Table
- SD Card Unit Table
- SD Card Device Table
- Device Group Variable Values
- Device Tables
- Slot Group
- Memory Group
- BIOS Setup Control Group
- Local Response Agent Group
- Cost of Ownership Group
- Cluster Group
- Baseboard Management Controller Group
- Field Replaceable Unit Group
- Storage Management Group
- Storage Management Group
- Storage Management Information Group
- Global Data Group
- Physical Devices Group
- Controller Table
- Channel Table
- Enclosure Table
- Array Disk Table
- Array Disk Enclosure Connection Table
- Array Disk Channel Connection Table
- Fan Table
- Fan Connection Table
- Power Supply Table
- Power Supply Connection Table
- Temperature Probe Table
- Temperature Probe Connection Table
- Enclosure Management Module Table
- Enclosure Management Module Connection Table
- Battery Table
- Battery Connection Table
- Tape Drive Table
- NVME adapter table
- Logical Devices Group
- Storage Management Event Group
- Change Management Group
- SNMP Traps
- Storage Management Alert Reference
- Standard Data Type Definitions
- SNMP Sample Output
Table 330. Chassis Type (continued)
tower(7)
The chassis type is a tower.
portable(8)
The chassis type is a portable.
lapTop(9)
The chassis type is a laptop.
noteBook(10)
The chassis type is a notebook.
handHeld(11)
The chassis type is a handheld.
dockingStation(12)
The chassis type is a docking station.
allInOne(13)
The chassis type is an all-in-one.
subNoteBook(14)
The chassis type is a subnotebook.
spaceSaving(15)
The chassis type is a spacesaver.
lunchBox(16)
The chassis type is a lunch box.
mainSystemChassis(1
7)
The chassis type is the main system chassis.
expansionChassis(18
)
The chassis type is an expansion chassis.
subChassis(19)
The chassis type is a subchassis.
busExpansionChassis
(20)
The chassis type is a bus-expansion chassis.
peripheralChassis(2
1)
The chassis type is a peripheral chassis.
raidChassis(22)
The chassis type is a disk RAID chassis.
rackMountChassis(23
)
The chassis type is a rack-mounted chassis.
sealedCasePC(24)
The chassis type is a sealed-case chassis.
multiSystemChassis(
25)
The chassis type is a multisystem chassis.
Table 331. Connection Status
Variable Name : DellConnectionStatus
Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(2)
The status of the chassis connection is unknown.
ok(3)
The status of the chassis connection is OK.
failure(4)
The status of the chassis connection is failure.
Table 332. Fan Control Capabilities
Variable Name : DellFanControlCapabilities
Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1)
The fan’s capabilities are unknown.
lowSpeedCapable(2)
The fan can be set to low speed.
highSpeedCapable(4)
The fan can be set to high speed.
Server Administrator Group 81