Reference Guide
Table Of Contents
- Dell EMC OpenManage SNMP Reference Guide Version 10.1.0.0
- Contents
- Introduction
- What is new in this release
- Supported SNMP Versions
- Managed Object Used in This Document
- Server Administrator Instrumentation MIB
- Server Administrator Baseboard Management Controller, ASF MIB
- Server Administrator Storage Management MIB
- Server Administrator Field Replaceable Unit MIB
- Server Administrator Change Management MIB
- Basic Terminology
- Frequently Used Terms in Variable Names
- Tables
- Section Organization
- Other Documents You May Need
- Introduction to the Server Administrator SNMP Subagent
- System Battery Table
- Amperage Probe Table
- Power Unit Group
- Power Supply Table
- Power Usage Table
- Voltage Probe Table
- System Information Group
- Server Administrator Group
- Instrumentation MIB Version Group
- Systems Management Software Group
- System State Group
- Chassis Information Group
- Operating System Group
- System Resource Group
- Power Group
- Thermal Group
- Remote Flash BIOS Group
- Port Group
- Device Group
- Device Tables
- Pointing Device Table
- Keyboard Device Table
- Processor Device Table
- Processor Device Status Table
- Cache Device Table
- Memory Device Table
- Memory Device Mapped Address Table
- Generic Device Table
- PCI Device Table
- PCI Device Configuration Space Table
- Network Device Table
- Managed System Services Device Table
- SD Card Unit Table
- SD Card Device Table
- Device Group Variable Values
- Device Tables
- Slot Group
- Memory Group
- BIOS Setup Control Group
- Local Response Agent Group
- Cost of Ownership Group
- Cluster Group
- Baseboard Management Controller Group
- Field Replaceable Unit Group
- Storage Management Group
- Storage Management Group
- Storage Management Information Group
- Global Data Group
- Physical Devices Group
- Controller Table
- Channel Table
- Enclosure Table
- Array Disk Table
- Array Disk Enclosure Connection Table
- Array Disk Channel Connection Table
- Fan Table
- Fan Connection Table
- Power Supply Table
- Power Supply Connection Table
- Temperature Probe Table
- Temperature Probe Connection Table
- Enclosure Management Module Table
- Enclosure Management Module Connection Table
- Battery Table
- Battery Connection Table
- Tape Drive Table
- NVME adapter table
- Logical Devices Group
- Storage Management Event Group
- Change Management Group
- SNMP Traps
- Storage Management Alert Reference
- Standard Data Type Definitions
- SNMP Sample Output
Table 299. Firmware Date Name
Name
firmwareDateName
Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.10
Description Defines the date of the firmware.
Syntax DellDateName
Access Read-only
Table 300. Firmware Version Name
Name
firmwareVersionName
Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.11
Description Defines the version name of the firmware.
Syntax DellString
Access Read-only
Intrusion Table
The following objects and attributes describe the different forms of chassis intrusion, a situation that occurs when the cover of
a computer is removed.
NOTE: The Drive Bay sensor is available on Dell PowerEdge R740xd2 systems only.
Table 301. Intrusion Table
Name
intrusionTable
Object ID 1.3.6.1.4.1.674.10892.1.300.70
Description Defines the Intrusion Table.
Syntax SEQUENCE OF IntrusionTableEntry
Access Not accessible
Table 302. Intrusion Table Entry
Name
intrusionTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.300.70.1
Description Defines the Intrusion Table entry.
Syntax IntrusionTableEntry
Access Not accessible
Index
intrusionchassisIndex
,
intrusionIndex
Table 303. Intrusion Chassis Index
Name
intrusionchassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.1
Description Defines the index (one-based) of this chassis.
Server Administrator Group 75