Reference Guide

Table Of Contents
Table 299. Firmware Date Name
Name
firmwareDateName
Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.10
Description Defines the date of the firmware.
Syntax DellDateName
Access Read-only
Table 300. Firmware Version Name
Name
firmwareVersionName
Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.11
Description Defines the version name of the firmware.
Syntax DellString
Access Read-only
Intrusion Table
The following objects and attributes describe the different forms of chassis intrusion, a situation that occurs when the cover of
a computer is removed.
NOTE: The Drive Bay sensor is available on Dell PowerEdge R740xd2 systems only.
Table 301. Intrusion Table
Name
intrusionTable
Object ID 1.3.6.1.4.1.674.10892.1.300.70
Description Defines the Intrusion Table.
Syntax SEQUENCE OF IntrusionTableEntry
Access Not accessible
Table 302. Intrusion Table Entry
Name
intrusionTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.300.70.1
Description Defines the Intrusion Table entry.
Syntax IntrusionTableEntry
Access Not accessible
Index
intrusionchassisIndex
,
intrusionIndex
Table 303. Intrusion Chassis Index
Name
intrusionchassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.1
Description Defines the index (one-based) of this chassis.
Server Administrator Group 75