Reference Guide
Table Of Contents
- Dell EMC OpenManage SNMP Reference Guide Version 10.1.0.0
- Contents
- Introduction
- What is new in this release
- Supported SNMP Versions
- Managed Object Used in This Document
- Server Administrator Instrumentation MIB
- Server Administrator Baseboard Management Controller, ASF MIB
- Server Administrator Storage Management MIB
- Server Administrator Field Replaceable Unit MIB
- Server Administrator Change Management MIB
- Basic Terminology
- Frequently Used Terms in Variable Names
- Tables
- Section Organization
- Other Documents You May Need
- Introduction to the Server Administrator SNMP Subagent
- System Battery Table
- Amperage Probe Table
- Power Unit Group
- Power Supply Table
- Power Usage Table
- Voltage Probe Table
- System Information Group
- Server Administrator Group
- Instrumentation MIB Version Group
- Systems Management Software Group
- System State Group
- Chassis Information Group
- Operating System Group
- System Resource Group
- Power Group
- Thermal Group
- Remote Flash BIOS Group
- Port Group
- Device Group
- Device Tables
- Pointing Device Table
- Keyboard Device Table
- Processor Device Table
- Processor Device Status Table
- Cache Device Table
- Memory Device Table
- Memory Device Mapped Address Table
- Generic Device Table
- PCI Device Table
- PCI Device Configuration Space Table
- Network Device Table
- Managed System Services Device Table
- SD Card Unit Table
- SD Card Device Table
- Device Group Variable Values
- Device Tables
- Slot Group
- Memory Group
- BIOS Setup Control Group
- Local Response Agent Group
- Cost of Ownership Group
- Cluster Group
- Baseboard Management Controller Group
- Field Replaceable Unit Group
- Storage Management Group
- Storage Management Group
- Storage Management Information Group
- Global Data Group
- Physical Devices Group
- Controller Table
- Channel Table
- Enclosure Table
- Array Disk Table
- Array Disk Enclosure Connection Table
- Array Disk Channel Connection Table
- Fan Table
- Fan Connection Table
- Power Supply Table
- Power Supply Connection Table
- Temperature Probe Table
- Temperature Probe Connection Table
- Enclosure Management Module Table
- Enclosure Management Module Connection Table
- Battery Table
- Battery Connection Table
- Tape Drive Table
- NVME adapter table
- Logical Devices Group
- Storage Management Event Group
- Change Management Group
- SNMP Traps
- Storage Management Alert Reference
- Standard Data Type Definitions
- SNMP Sample Output
Table 240. Chassis Reseller System ID
Name
chassisResellerSystemID
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.43
Description Defines the chassis reseller system ID.
Syntax DellUnsigned16BitRange
Access Read-only
Table 241. Chassis NMI Button Control Capabilities Unique
Name
chassisNMIButtonControlCapabilitiesUnique
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.44
Description Defines the capabilities of the NMI button control function.
Syntax DellNMIButtonControlCapabilities (See NMI Button Control Capabilities)
Access Read-only
Table 242. Chassis NMI Button Control Settings Unique
Name
chassisNMIButtonControlSettingsUnique
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.45
Description Defines the current reading and allows setting of the NMI button control hardware.
Syntax DellNMIButtonControlSettings (See NMI Button Control Settings)
Access Read-only
Table 243. Chassis System Properties
Name
chassisSystemProperties
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.46
Description Defines the properties of the system.
Syntax DellSystemProperties (See System Properties)
Access Read-only
Table 244. Chassis System Revision Number
Name
chassisSystemRevisionNumber
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.47
Description Defines the revision number of the system where zero indicates the original version of
the system. The revision number is not available on all systems.
Syntax DellUnsigned8BitRange
Access Read-only
Table 245. Chassis System Revision Name
Name
chassisSystemRevisionName
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.48
Description Defines the revision name of the system, if applicable.
Syntax DellString
Access Read-only
Server Administrator Group 63